| 1 | DC fan  | 10 | 36 | 360 | 6 | 2160 | 
	| 2 | Energy Saver Lights  | 10 | 12 | 120 | 6 | 720 | 
	 |  |  |  | 480 |  | 2880 | 
	 |  |  |  |  |  |  | 
	 | Load =  |  |  |  | 2880 | WH | 
	 | Current required for Aplinces | Total watts/System voltage  |  |  | 40 | A | 
	 | Average daily sunny hours in project area |  |  |  | 12 | hrs  | 
	 | Required Backup time |  |  |  | 2 | hrs  | 
	 | System Voltage  |  |  |  | 12 | V | 
	 | Design of Battery |  |  |  |  |  | 
	 | Backuptime (Hr)xLoad(watts)/System voltage  |  |  |  | 80 | Ah | 
	 | add Eff. @ 90 % |  |  |  | 100 | Ah | 
	 | add 80 % DoD |  |  |  | 125 | Ah | 
	 | Des Amp. Hrs |  |  | Say  | 125 | Ah | 
	 | Proposed Battery Size  |  |  |  | 110 | Ah | 
	 | No of Batteries  |  |  |  | 1.13636363636 | No | 
	 |  |  |  | Say  | 1 | No | 
	 | Design of Solar Panels |  |  |  |  |  | 
	 | Current required for Applinces = total watts/system voltage |  |  |  | 40 | A | 
	 | Current required for Battery = 60% DoD/average daily sunny hrs |  |  |  | 10.4166666667 | A | 
	 | Total current required  |  |  |  | 50.4166666667 | A | 
	 | Lets Take currents for applinces  |  |  |  |  |  | 
	 | Power for Solar Panel required = total current required x system voltage |  |  |  | 480 | W | 
	 | add 20 % losses (  lossess + conductor effeiciency)  |  |  |  | 576 | W | 
	 | Proposed Size of panel  |  |  |  | 250 | No | 
	 | No of Panels |  |  |  | 2.304 | No | 
	 |  |  |  | Say  | 2 | No | 
	 | Design of  Charge Controller |  |  |  | 48 | A | 
	 | Proposed Size of Charge controler  |  |  |  | 60 | A | 
	 | No  of Charge Controlers |  |  |  | 0.8 | No | 
	 |  |  |  | say  | 1 | No | 
	 | for safety of battery proposed 01 charge controlers of 12v/60A.  |  |  |  |  |  |